Food & Beverage Home → ATP Tests → UltraSnap™
Surface ATP Test
UltraSnap™ is a user-friendly, all-in-one ATP sampling test used with Hygiena luminometers. This pen-sized sample collection device is easy to use, small, and environmentally friendly. In addition, UltraSnap uses a unique liquid-stable reagent providing superior accuracy, longer-lasting signal strength, and more reproducible results.
View & Download Full Product Catalog
What is ATP testing?
Adenosine Triphosphate, or ATP, is the energy molecule found in all living things, making it a perfect indicator when trying to determine if a surface is clean or not. Food and beverage processors use ATP systems to rapidly verify surfaces have been cleaned thoroughly so that new product runs are not contaminated by prior product runs, and to ensure biofilms are not developing on the surface that could affect quality.
With an ATP hygiene monitoring system, (or sometimes referred to as - an ATP sanitation monitoring system), ATP is brought into contact with Hygiena's unique liquid-stable reagent in the test device. Light is then emitted in direct proportion to the amount of ATP present in the sample, providing information on the level of contamination in seconds.
A clean start each day.
A clean production environment is a key component to producing safe, quality foods. By incorporating ATP monitoring into preoperative equipment inspection and changeover cleaning verification, quality personnel can confirm cleanliness in seconds. Your facility is only as clean as you start, so it's best to start the day right.
Swab, snap, squeeze. It's that easy.
Using UltraSnap couldn't be easier. The three step process for collecting a sample,
activating the device, and mixing the sample is so easy, anyone can do it. See an instructional video.
Liquid-stable chemistry.
UltraSnap contains liquid-stable chemistry in the patented Snap-Valve™ bulb. This unique chemistry and design eliminates the need to reconstitute lyophilized pellets, enabling consistent and accurate results. Learn more about liquid-stable chemistry.
Compare to other ATP tests.
Don't take our word for it! See how UltraSnap compared to other ATP tests in the largest ATP study ever done. Learn more ...
Affordability to fit any size budget.
Patented design and uniquely formulated chemistry gives UltraSnap superior performance at a price that can fit into any quality assurance program. When implementing an ATP program, decisions need to be made about the amount of testing necessary to accurately monitor the production environment, but also meet budget allocation. Hygiena's luminometers and UltraSnap testing device have been specifically designed to meet testing needs as well as budget constraints. Contact us for a quote or for help setting up an ATP hygiene monitoring program to fit your budget.
Need more sensitivity for monitoring allergens on surfaces or sterile environments?
For rapid validation of allergen removal, confirmation of cleanliness after terminal cleaning, or when dealing with harsh samples, SuperSnap™ can provide that extra level of sensitivity and robustness you need.
Benefits
- Costs up to 50% less than other ATP swabs
- Results in 15 seconds
- Consistent, reliable results
- Pre-moistened swab bud
- Self-contained, liquid-stable reagent
- Write-on swab label for easy sample identification
- Environmentally conscious design - uses 20 - 80% less plastic than comparable devices
- Recyclable #7
- Patented Snap-Valve™ technology - snap & squeeze
- Unprecedented accuracy and reproducibility
- Tolerant to temperature abuse
- Test wet or dry surfaces
Specifications
- High sensitivity: Detects 0.1-1 femtomoles of ATP
- For detection to 0.1 femtomoles of ATP, use EnSURE™
- For dectection to 1 femtomoles of ATP, use SystemSURE
- Shelf life:
- 15 months at refrigerated temperatures (2-8 ºC)
- 4 weeks room temperature (21-25 ºC)
-
Compatible Luminometers
Resources
Help Getting Started
Instructions
Product Brochure
Safety Data Sheet (SDS)
- UltraSnap SDS - English
- UltraSnap SDS - Spanish
- UltraSnap SDS - Russian
- UltraSnap SDS - Portuguese
- UltraSnap SDS - Moroccan/Arabic
- UltraSnap SDS - Italian
- UltraSnap SDS - German
- UltraSnap SDS - French
- UltraSnap SDS - Chinese
AOAC PTM Validated Method Information
Technical Documents
- Lower and Upper RLU Limits for ATP Monitoring Programs
- Technical Document: Detection of Yeasts by Hygiena ATP Test Devices | Spanish
- Sanitizer Effects on Hygiena ATP Test Devices | Spanish
Research
Editorial Features
- Novel Developments in ATP Bioluminescence
- Precision and Accuracy in ATP Hygiene Testing
- Rapid Hygiene Tests in Support of Food Safety - Exploding the Myths About ATP Hygiene Monitoring
- ATP Hygiene Monitoring: Do Sanitizers Really Affect Measurements?
- Hygiene Monitoring in Support of Food Safety: A Review of Methods and Industry Trends
- What Makes a Good ATP Hygiene Monitoring System?
- Hygiene Swabbing -- How valid is it? / Sources of Bacteria
- ATP Testing Systems for Measuring Cleanliness
- Listeria Guidance & Best Practices in Produce Facilities
- Minimizing Microbiological Risks in Multiple-Use Containers
- Environmental Monitoring Self Assessment - FSMA Prep
- What Really Matters in ATP Hygiene Monitoring
- International Food Hygiene Magazine Series:
Case Study