Food Safety
Reusing process water? Add it to your allergen risk assessment
Quick Answer
Reused process water is a potential allergen cross-contact pathway, though its extent has not been measured. Food plants reuse wash, flume and immersion water for 1 to more than 50 cycles, and treatment systems are built to control pathogens and chemicals, not allergenic proteins. If the same water contacts allergen-containing and allergen-free products, include it in your allergen risk assessment.
Why is water reuse growing in food processing?
Water is one of the largest operating costs in food manufacturing. Washing, chilling, peeling, conveying and cleaning all depend on it. CIP alone can account for 30 to 80% of operating costs and up to 70% of a plant's water use. Reconditioning water so the same supply can serve many batches cuts both cost and environmental impact.
International guidance now supports water reuse in food processing.. The Codex Guidelines for the Safe Use and Reuse of Water in Food Production and Processing (CXG 100-2023) set out a risk-based approach to choosing water that is fit for its intended use. In January 2026, agriculture ministers from 59 countries at the Global Forum for Food and Agriculture explicitly encouraged use of these guidelines.
Water reuse can support resource efficiency when the water is fit for its intended use. Allergen carry-over is another consideration when assessing shared systems.
Can allergens survive water treatment?
Water treatment in food plants is usually built around microbiological quality: disinfection, filtration and pathogen control. A system’s effectiveness against microbiological or chemical hazards should not be taken as evidence that it also removes allergenic proteins.
That matters because many allergens are stable by nature. Strong disulfide bonds and compact folded structures help them resist heat, enzymes and changes in pH. The peanut proteins Ara h 2 and Ara h 6, for example, are extremely resistant to breakdown because of four highly stable disulfide bonds.
Allergen removal depends on membrane characteristics, protein size and interactions such as adsorption and charge. Membrane specifications alone do not establish removal performance.
There is related evidence from a different reused medium. Studies have shown cashew protein, shellfish tropomyosin and gluten transferring into reused frying oil and persisting at levels that cross-contaminate other products.
Still, this is an open question, not a proven risk. The authors identify limited evidence on allergen occurrence and transfer in reused food-processing water. That gap is exactly why it deserves attention now.
What do the new Codex allergen labeling guidelines mean for process water?
In July 2026, the Codex Alimentarius Commission adopted Guidelines on the Use of Precautionary Allergen Labelling as an annex to the General Standard for the Labelling of Pre-packaged Foods (CXS 1-1985). The guidance supports a science-based approach to precautionary labeling informed by FAO/WHO reference doses.
Under this approach, "may contain" statements are meant for cross-contact that cannot be avoided, and labeling decisions depend on how much allergen could realistically be present. That only works if you know where cross-contact can come from.
For manufacturers, that makes the question concrete. If the same water contacts products with different allergen profiles, it is a potential cross-contact pathway. Whether it matters has not been measured, but it is the kind of pathway a labeling decision is supposed to account for.
In the US, the FDA held a public meeting on food allergen thresholds in February 2026, and allergen cross-contact is already a hazard manufacturers must control under FSMA preventive controls. Codex guidance is not law in itself. It sets an international reference point that national regulators adopt in different ways, so check the requirements that apply in your destination markets.
For background on reference doses and how they change allergen decisions, see our guide to building a modern risk-based allergen management program.
Which processes warrant closer assessment?
The npj Clean Water paper ranks common water-intensive processes by their potential for allergen carry-over, based on water contact, reuse frequency and how much protein each step releases.
The authors are clear that this ranking is conceptual. It shows where carry-over is more likely, not where consumer risk has been measured.
|
Process |
Typical reuse cycles |
Conceptual potential for allergen carry-over |
| Dunk tanks and immersion | 5 to 20 | Very high |
| Produce flumes and conveyors | 10 to 50+ | High |
| Dehusking, shelling and peeling | 1 to 10 | High |
| Raw product washing | 1 to 20 | Medium |
| Poultry and meat processing | 1 to 15 | Medium |
Two patterns stand out. Processes with long, close contact between product and water let proteins build up. Processes that break open tissue, such as shelling, peeling and cutting, release more protein into the water in the first place.
Where should you look first?
These four segments provide examples of where shared water systems may warrant assessment, depending on the products and processes involved.
Nut and ingredient processing
Nut plants often run peanuts and several tree nuts through the same dunk tanks, blanching water or shelling lines. Shelling and blanching break down tissue and release protein into the water. Peanut and hazelnut proteins are among the most breakdown-resistant allergens studied.
Questions to consider: Does blanching or soak water carry over between products with different allergen profiles? If it does, is that pathway currently reflected in your allergen risk assessment and changeover procedures?
Seafood processing
Fish and crustacean shellfish are separate regulated allergens, and many plants handle both. Thawing, washing and immersion water can serve several species in one shift. Fish parvalbumin and shellfish tropomyosin are both highly stable proteins. Learn more about allergen and hygiene testing for seafood.
Questions to consider: Does thaw or wash water move between finfish and shellfish lines? If it does, has that pathway been considered when setting controls and labeling for products carrying only one of the two?
Fresh-cut produce and salad kits
Produce flumes have the highest reuse cycles in the paper, often 10 to more than 50. Produce itself is rarely the allergen, but salad kit plants also bring in components like nuts, cheese and croutons. Earlier research has already profiled vegetable wash water for possible allergen carry-over.
Questions to consider: Do allergen-containing kit components share any water system with produce? If they do, do you track reuse cycles and replacement points for that system, and is the pathway noted in your risk assessment?
Dairy
Dairy plants are some of the heaviest users of CIP and water recovery. The main whey protein, beta-lactoglobulin, is a model for protein persistence. For example, a dairy plant that also runs plant-based or milk-free lines may share recovered water between them.
Questions to consider: Is recovered water from dairy lines used on milk-free lines? If it is, does your current CIP validation scope include the recovery loop?
How do you add reused water to your allergen risk assessment?
You don't need new science to start. You need visibility.
- Map where reused water contacts product. List every system where water is recirculated and every product it touches.
- Identify allergen changeovers on shared water. Flag shared water loops serving products with different allergen profiles, including products intended to exclude a particular allergen.
- Record reuse cycles and full replacement points. Know how long water stays in the system and when it is fully refreshed.
- Consider whether your cleaning verification covers water-contact surfaces. Many programs verify product-contact surfaces but not tank walls, flume channels or other surfaces on shared water loops. Whether those belong in your program is a judgement call today, and there is no validated method for testing the water itself.
- Review PAL decisions for exposed products. Under a reference dose approach, unassessed cross-contact sources weaken the case for any labeling decision.
- Document your reasoning. A written assessment gives auditors, customers and your own team a clear record of what was considered and why.
What still needs to be answered?
The paper sets out a research agenda. It proposes indicator allergens for monitoring water systems, including whey, egg, peanut, hazelnut and sesame proteins that resist breakdown. It calls for methods validated in water matrices and for online measures such as organic carbon, turbidity and fluorescence that could act as early warning signs.
Hygiena scientists Jennine Cannizzo, Julie Weller and Daniel Wing co-authored the review with Rasha Maal-Bared and colleagues.
The full paper is open access in npj Clean Water.
Is reused process water part of your allergen risk assessment? Discuss your allergen verification program with our experts.